QiO™ - CAN I/O CONVERTERTOOLREC HUBGP4 CONTROLLERGP1 CONTROLLERGP CONTROLLERCAN GATEWAYTOOLREC MODULE (TRM)
TOOLREC HUBGP4 CONTROLLER
Datasheet:QIO_Data_sheetData_sheet-ToolRecData_Sheet_GP4GP1_CAN_3xM8_C
GP1_1xM8.2xM12
GP1_Exp_B
Data_sheet_GPCData_Sheet_GatewayData_sheet-ToolRec

Short description:

The QIO™ - CAN I/O Converter converts CAN data to analog/digital signals, facilitating integration with systems or direct control.Acts as a bridge between a bluetooth network and a CAN
network.
Universal valve controller
for earth-moving machinery with 3D angle sensing technology.
Universal central
controller for earth-moving machinery.
Universal central
controller for earth-moving machinery with display and buttons for programming.
Translates CAN traffic
between two separated CAN-busses running at different speeds, CAN-protocols, terminations and supply voltages.
Mounted on the various heavy machinery work tools. Supply a 6 byte unique ID over the ether using BTLE protocol.

Proportional bidirectional outputs:

N/AN/A415N/AN/A

On/Off outputs:

8N/A224N/AN/A

CAN buses:

221112N/A

No. of CAN ports:

332Alt. 1: 4
Alt. 2: 2
Alt. 3: 1
23N/A

No. of digital inputs:

62259N/AN/A

No. of analog inputs:

5 (digital input can be used as analog input)N/A2Alt. 1: 2
Alt. 2: 12
Alt. 3: 2
8N/AN/A

Communication:

CANCAN, BTLECANCANCANCANBTLE

Accelerometer:

NoNoAlt. 1: Yes
Alt. 2: No
NoNoNoYes

Gyroscope:

NoNoNoNoNoNoYes

ELECTRICAL DATA

Nominal voltage:

12 and 24 V12 and 24 V12 and 24 V12 and 24 V12 and 24 V12 and 24 V3.6 V

Supply voltage:

8-36 V7.5-36 V8-36 V8-36 V9-30 V8-36 V1.8-3.6 V

Quiescent current at 12 V:

Up to 170 mAUp to 100 mAUp to 120 mAUp to 170 mAUp to 150 mAN/A

Quiescent current at 24 V:

Up to 80 mAUp to 55 mAUp to 105 mAUp to 80 mAUp to 80 mAN/A

CAN termination
resistance:

"600 Ω/120 Ω
or none, configurable by software"
Software selectable 120 Ω, 600 Ω, not terminatedAlt. 1: 120 Ω
Alt. 2: 600 Ω
600 Ω620 ΩSoftware selectable 120 Ω, 600 Ω, not terminatedN/A

Input resistance:

10 kΩ10 kΩ10 kΩ10 kΩ10 kΩN/AN/A

Battery operating life:

N/AN/AN/AN/AN/AN/AUp to 5 years depending on usage and environment

ENVIRONMENTAL DATA

Water / dust rating:

IP23IP50 (acc. to IEC60529)IP67(with assembled
mating connectors)
IP50 (with assembled
mating connectors)
-IP50 (with assembled
mating connectors)
IP67 (acc. to IEC60529)

Operation temperature:

-40º C - 85° C-40° to +70° C-40° to +70° C-40° to +70° C-40° to +70° C-40° to +70° C-40° to +70° C

Humidity:

IEC60068-2-38
IEC60068-2-78
IEC60068-2-30
IEC60068-2-78
IEC60068-2-38
IEC60068-2-78
IEC60068-2-38
IEC60068-2-78
-IEC60068-2-38
IEC60068-2-78
IEC60068-2-30
IEC60068-2-78
IEC60068-2-38

Vibration:

IEC60068-2-64IEC60068-2-64IEC60068-2-64IEC60068-2-64-IEC60068-2-64Field tested to withstand very tough environments (as a hydraulic hammer).

Shock:

ISO 16750-3IEC60068-2-27,
500m/s2 - 6msec
N/AN/A-N/AIEC62262, IK09, 10 joule
(TRM metal cover provides
additional protection)

Drops:

IEC60068-2-31IEC60068-2-31IEC60068-2-31IEC60068-2-31-IEC60068-2-31IEC60068-2-31

COMPLIANCE

RED

2014/53/EU2014/53/EU

RoHs

2011/65/EU2011/65/EU

WEEE

2012/19/EU2012/19/EU

FCC

USA FCC Class BUSA FCC Class B

ICES

CAN ICES-3 (B) / NMB-3 (B)CAN ICES-3 (B) / NMB-3 (B)

LVD

2014/35/EU2014/35/EU

EMC

2004/108/EU2004/108/EU

STANDARDS

Radio

ETSI EN 300 328 V2.1.1
ETSI EN 301 489-1 V2.1.1
ETSI EN 301 489-17 V3.1.1
ETSI EN 300 328 V2.1.1
ETSI EN 301 489-1 V2.1.1
ETSI EN 301 489-17 V3.1.1

EMI

ISO 13766-1:2018ISO 13766-1:2018

RoHs

EN 50581:2012EN 50581:2012

Electrical safety

EN 60950-1EN 60950-1